Technical Characterisics Table
Working Preasure(Vaccum)
|
|
Working Temeerature
|
|
Dimension Table mm
NominalVolume
VN
|
Dimension
|
D1
|
D2
|
D3
|
H
|
H1
|
H2
|
H3
|
H4
|
H5
|
H6
|
H7
|
t
|
t1
|
1.5m3
|
1300
|
1608
|
30
|
2740
|
1460
|
1460
|
600
|
250
|
400
|
400
|
600
|
14
|
14
|
2 m3
|
1300
|
1608
|
30
|
3730
|
1860
|
1860
|
600
|
250
|
400
|
400
|
600
|
14
|
14
|
2.5 m3
|
1450
|
1714
|
30
|
4012
|
2095
|
2095
|
800
|
250
|
400
|
400
|
800
|
14
|
14
|
3 m3
|
1450
|
1714
|
30
|
4860
|
2420
|
2420
|
800
|
250
|
400
|
400
|
800
|
14
|
14
|
4 m3
|
1600
|
1952
|
30
|
6180
|
3080
|
3080
|
850
|
300
|
400
|
500
|
850
|
16
|
16
|
Nozzle Specirrcetion and Service mm
|
a1、2
Circulation
|
b
Inlet hole
|
c
Waccum pump
|
d
Hole for
Vaccum pump
|
S2,S2
Sigth glass
|
T
Temperature
Measure Hole
|
g
Outlet hole
|
M
Man hole
|
1.5m3
|
150
|
80
|
-
|
300
|
125
|
-
|
200
|
-
|
2 m3
|
150
|
65
|
65
|
125
|
125
|
65
|
200
|
300×400
|
2.5 m3
|
150
|
80
|
-
|
300
|
125
|
-
|
200
|
-
|
3 m3
|
150
|
80
|
-
|
300
|
125
|
-
|
200
|
-
|
4 m3
|
150
|
80
|
125
|
400
|
125
|
125
|
200
|
-
|
|